sales@sorbentra.com Wenchang, Hainan, China
Activated carbon export inquiries · SORBENTRA & private label
Request a quote
AC-A460SORBENTRA product

Coal-based 4 mm activated carbon pellets

Steam-activated coal-based pellets for general VOC adsorption, solvent vapor and non-acidic odor control in fixed-bed systems. Supplied in SORBENTRA branded export packaging.

Primary application
General VOC carbon adsorber replacement media
Supply basis
Agreed specification and approved sample
Packaging
SORBENTRA branded or private label

Final values, test methods, packaging and delivery terms are confirmed in the quotation and signed order specification.

Illustration of four millimeter extruded activated carbon pellet form Product format reference
MaterialCoal based
ActivationSteam activated
Format4 mm; final tolerance and method confirmed in the order specification
Product-format reference. The approved sample and signed order specification control commercial supply.

Product overview

Core format, application and buying specification.

Use these fields as the starting specification. If you already buy against a TDS or COA, send it with the inquiry so the quoted grade can be aligned to the same methods and acceptance basis.

Base material
Coal based
Activation
Steam activated
Form
Extruded activated carbon pellet
Nominal diameter
4 mm; final tolerance and method confirmed in the order specification
Impregnation
Unimpregnated
Intended duty
General VOC, solvent vapor and non-acidic odor duty
Supply format
SORBENTRA branded export packaging

Need different values? Send the required limits and test methods for a specification-matched quotation.

Application fit

Recommended applications and selection notes.

The contaminant, equipment and operating conditions determine whether this standard grade fits or a different activated carbon is required.

DutyPositionDecision basis
General VOC carbon adsorber replacement mediaRecommendedProceed after comparing the contaminant mix, concentration, humidity, airflow, bed depth and incumbent media.
Solvent vapor including aromatic-organic dutyReview requiredUse relevant capacity or breakthrough testing under representative conditions; do not select from CTC alone.
Non-acidic industrial odor controlRecommendedIdentify the actual odor compounds and confirm that physical adsorption is the appropriate mechanism before testing.
Hydrogen sulfide, sulfur dioxide, ammonia, mercury or acid gasesSpecial grade requiredThese duties commonly require impregnated or chemically reactive media. AC-A460 is unimpregnated.
Thin-panel or shallow carbon filtersReview requiredA 4 mm pellet may not suit the layer thickness, retention screen or pressure-drop envelope of a thin filter.

Quotation inputs

Tell us what the carbon needs to do.

  • VOC or odor compounds, inlet concentration, variability and required outlet or changeout trigger.
  • Airflow, temperature, relative humidity, pressure-drop limit and operating schedule.
  • Adsorber dimensions, bed depth, loading method and current media specification.
  • Observed service life, reason for replacement and spent-carbon handling constraints.
  • Trial quantity, annual estimate, packaging, destination port and required shipment documents.

Order path

From specification to delivery.

  1. 01

    Review the contaminant, airflow, equipment and current media.

  2. 02

    Confirm the quotation basis, packaging and requested document set.

  3. 03

    Approve pellet form, dust level and representative sample results.

  4. 04

    Sign the order specification, handling controls and inspection plan.

  5. 05

    Release production, batch documents and export delivery against the approved order.

Sample and documents

The technical file follows the approved grade.

Sample identity, order limits and shipment documents are aligned to the same product reference and buyer-approved specification.

01 / Sample

Sample package

Representative product sample, sample COA and agreed comparison methods for laboratory or plant review.

02 / Order

Order specification

Approved values, test methods, packaging, inspection points and acceptance criteria.

03 / Shipment

Shipment documents

English TDS, SDS and batch COA plus packing, labeling and export documentation.

Product FAQ

Questions procurement teams ask first.

Is AC-A460 an impregnated activated carbon pellet?

No. AC-A460 is an unimpregnated, steam-activated coal-based pellet for general VOC and non-acidic odor duty. Reactive gases normally require a separately selected impregnated grade.

Can AC-A460 be supplied to a target CTC value?

Yes, the quotation can be prepared against a buyer-specified CTC value and related physical properties. Final values, methods and tolerances are confirmed in the signed order specification after sample review.

What information is needed for VOC carbon adsorber replacement media?

Provide the contaminant mix, inlet concentration, temperature, relative humidity, airflow, adsorber dimensions, bed depth, current media, changeout trigger and target service life. This information is needed before a 4 mm pellet can be treated as a serious candidate.

Can the pellets be used for all industrial odors?

Odor chemistry matters. AC-A460 is offered for general VOC, solvent vapor and non-acidic odor duties after application review. Reactive, acidic or highly specific contaminants may need an impregnated carbon or another adsorbent.

Commercial inquiry

Request a AC-A460 quotation.

Send the current specification, operating conditions, expected quantity and destination. We will confirm the next product, sample and quotation step.